This high performance cooled digital 12 bit CCD camera system comprises advanced CCD and electronics technology. The system features thermo-electrical cooling of the image sensor (down to – 12 °C), extremely low noise (down to 4 e- rms) and an outstanding quantum efficiency, which achieves a high spectral sensitivity in general and especially in the NIR. Exposure time modes (software selectable) range from 500 ns (fast shutter) to 3600 s (long exposure). A high speed serial data link connects the system to the PC (fiber optic link available). This low light camera system is perfectly suited for many sensitive and low noise imaging applications, such as fluorescence imaging, confocal & light microscopy etc..
» Datasheet |
» 1288 Sheet |
» Software |
» Drivers |
» Manuals |
» FAQs |
» Publications |
» Where to get the product
Areas of Application
- laser induced fluorescence
- fluorescence microscopy
- electron microscopy
- red & NIR fluorescence applications
- bioluminescence / chemoluminescence
- spectroscopy
- gel imaging
- ion imaging
- low light level imaging
- semiconductor quality control
- imaging of bio markers (e.g. GFP)
| unit | setpoint | sensicam qe |
|---|
 |
| resolution (hor x ver) | pixel | | 1376 x 1040 |
| pixel size (hor x ver) | µm² | | 6.45 x 6.45 |
| peak quantum efficiency | % | @ 500 nm typical | 62 |
| dynamic range A/D | bit | | 12 |
| readout noise | e- rms | @ gain high @ gain low | 4 .. 5 5 .. 6 |
| imaging frequency, frame rate | fps | @ full frame @ binning 2 x 2 | 10 19.8 |
| exposure time | s | | 500 ns .. 3600 s |
| binning horizontal | | | 1, 2, 4, 8 |
| binning vertical | | | 1, 2, 4, 8, 16 |
| optical input | | | C-mount, Nikon adapter |
| data interface | | | PCI local bus, Rev. 2.1 |
| cooled CCD temperature | °C | | -12 |

Quantum efficiency curves of the sensicam qe CCD image sensor in two different operating modes (measured by pco).
» Datasheet |
» 1288 Sheet |
» Software |
» Drivers |
» Manuals |
» FAQs |
» Publications |
» Where to get the product
Fluorescence images with multi-spectral probes
Fluorescence image (false color coded) showing Indian Muntjac deer epidermis fibroblast cell stained with Alexa Fluor 568 - PMP 70 (Rb), Cy2 - Histones (Ms) and Alexa Fluor 350 - Phalloidin.
...with friendly permission of:
The Cooke Corporation, www.cookecorp.com
Rat Brain Section
Fluorescence image (false color coded) showing a rat brain sagittal 8 µm section stained with Alexa Fluor 568 - GFAP (Ms), Alexa Fluor 488 - NF-H (Ch) and Hoechst 33342.
...with friendly permission of:
The Cooke Corporation, www.cookecorp.com
Mouse Endothelial Cells
Fluorescence image (false color coded) showing mouse endothelial hemangioendothelioma cell stained with Alexa Fluor 568 - Tubulin (Ms), Alexa Fluor 750 - PMP 70 (Rb; Yellow) and DAPI.
...with friendly permission of:
The Cooke Corporation, www.cookecorp.com
Glia & Neurons
Glia (red) and neurons (green) are visible in a dog hippocampus slice.
...with friendly permission of:
Gloria E. Hoffman and colleagues, Maryland School of Medicine, Baltimore, USA
Single Molecule Spectroscopy
An area of 50µm x 50µm visible, the bright peaks correspond to single Terrylene molecules - single-molecule spectroscopy at low temperatures.
...with friendly permission of:
Institute for Experimental Physics IV, L. Kador & M. Bauer, University Bayreuth, Germany, www.ep4.phy.uni-bayreuth.de
» Datasheet |
» 1288 Sheet |
» Software |
» Drivers |
» Manuals |
» FAQs |
» Publications |
» Where to get the product